Beschreibung
CITY Hydrogen sulfide Gas Sensor 7HH
Merkmale
Hydrogen sulfide Gas Sensor
Ursprungsort
United Kingdom
Markenname
CITY TECHNOLOGY
Theorie
Hydrogen sulfide Gas Sensor
品名
Hydrogen sulfide Gas Sensor
Merkmale
Hydrogen sulfide Gas Sensor
Operating Principle
3-electrode electrochemical
Measurement Range
0-50 ppm H2 S
Maximum Overload
500 ppm H2 S
Sensitivity*
1.7 ± 0.3 uA/ppm
Response Time (T90 )*
<30 Seconds at 20°C
Baseline Offset (clean air)*
-0.2 to +0.4 ppm H2 S equivalent
Zero Shift (+20°C to +40°C)
< 0.1 ppm H2 S equivalent
Resolution
0.1 ppm (when used with recommended electronics)
Repeatability
1% of signal